Generator Simulation: Wind, Drop & Efficiency
Turn a falling weight, wind, or water into electricity. How efficient is your design, and what does it cost?
An electromagnetic generator converts mechanical shaft work into electrical energy via induced EMF proportional to rotation speed (emf = K omega), while electrical load current creates back-torque that brakes the rotor and peaks efficiency at an intermediate load resistance. This 3D generator simulation combines a falling-mass drop rig, a wind turbine simulation bench, and a village power planner to trace every joule of loss.
- 11 languages
- Laptop · tablet · phone
- Members
Create a free account to get 2 lifetime Free Lab Passes for any labs in the library. The course guide on this page stays free.

Inside this lab
- 1
Preview
- Driving question
- What you will predict
- Equipment and safety
- 2
Lab
- Lock in prediction
- Run the experiment, measure and replay
- Your notebook fills in as you go
- 3
Check
- Did the lab agree with you?
- Claim, evidence, reasoning
- Check questions and a printable lab report
How does a generator work? EMF, back-torque, and the efficiency formula
Understanding how does a generator work starts with two coupled equations: mechanical rotation generates an electromotive force (emf = K omega), and load current I = emf / (R_a + R_s + R_load) creates magnetic braking torque tau = K I opposing the shaft. Applying the efficiency formula eta = E_out / E_in across the full conversion chain (eta = eta_1 * eta_2 * eta_3) reveals where every joule of gravitational energy m g h goes—split among load output E_load, armature coil heat (R_a = 12 ohm), bearing friction (T_c, b), and landing impact E_impact. On the companion wind turbine simulation station, the same generator physics couples to aerodynamic torque (P_wind = 1/2 rho A v^3, Betz limit 16/27 = 59.3%).
Apparatus, safety notes, and step-by-step procedure
- Apparatus: Drop Generator rig (hooked masses
0.20,0.50,1.00 kg; stepped drum radii1.0,2.0,3.0 cm; drop height0.20–1.50 m; generatorK = 0.60 V·s/rad,R_a = 12 ohm,T_c = 0.03 N·m,b = 0.004 N·m·s/rad; loadsshort,4.7–470 ohm,open; 50 Hz energy sensorR_s = 0.1 ohm); Wind Turbine bench (0.20 mrotor;2,3,6blades; pitch5°,15°,30°;MED/HIGHfan at1–3 ft; loads10–100 ohm,open); and Village power planner (400 kWh/daydemand, hydro Sites A/B/C, ridge/valley wind, geothermal, diesel). - Safety note (for physical lab prep): When running a classroom falling-mass generator or model wind turbine, keep feet clear of the drop zone, wear safety goggles near spinning turbine blades, and never short high-output generators under heavy mechanical drive.
- Open the Drop station in Ideal mode with
m = 1.00 kg, drum radiusr = 0.020 m, drop heighth = 1.00 m(E_in = 9.800 J), and load set toopen. - Release the mass and record fall time (
2.31 s), landing speed (0.680 m/s), load energy (0.000 J), and efficiency (0.0%); note how fast the mass falls without electromagnetic braking. - Repeat the
1.00 kg,1.00 mdrop across load resistances10 ohm,22 ohm,47 ohm, and100 ohm; record fall time, landing speed,E_out, andeta = E_out / E_infor each trial. - Observe how lowering load resistance slows the falling mass (stronger current increases back-torque
K I), and verify that efficiency peaks near47 ohm(39.6%) and22 ohm(39.1%) while dropping at both10 ohm(30.6%) and100 ohm(32.0%). - Inspect the complete energy ledger (
E_load,E_coil,E_gear,E_impact) to verify all terms sum toE_in = 9.800 Jwith zero residual. - Switch to the Wind station (
HIGHfan at1 ft,v = 4.50 m/s), compare2,3, and6blades at5°,15°, and30°pitch, and sweep load resistance (10–100 ohm) after rotor speed stabilizes to maximizeP_outandeta = P_out / P_wind. - Move the fan from
1 ft(4.50 m/s) to2 ft(3.00 m/s) and3 ft(1.75 m/s) onHIGH, verifying thatP_winddrops withv^3. - Switch to Real mode on the Drop or Wind rig to observe kit friction/EMF variations and sensor quantization (
0.016 V,0.52 mA). - Open the Village station to design a renewable + firm-power mix meeting
400 kWh/day,40 kWevening firm power, emissions<= 20 t CO2e/yr, and river-reach<= 1.0 km.
Recording table and model reference data
Model reference data — run your own trials in the 3D lab. Values below reflect Ideal mode (
PHY-023), Drop Generator rig (m = 1.00 kg,r = 0.020 m,h = 1.00 m,E_in = 9.800 J,R_a = 12 ohm,R_s = 0.1 ohm).
| Trial | Independent Variable (Load Resistance R_load) | Dependent Variable (Fall Time, Landing Speed v_land, E_out, eta) | Units | Observation |
|---|---|---|---|---|
| Ref 1 | 10 ohm load | t = 6.38, v_land = 0.164, E_out = 2.996, eta = 30.6% | s, m/s, J, % | Strong magnetic braking, but large current wastes heat in 12 ohm coil |
| Ref 2 | 22 ohm load | t = 4.76, v_land = 0.228, E_out = 3.835, eta = 39.1% | s, m/s, J, % | High electrical yield with controlled landing speed |
| Ref 3 | 47 ohm load | t = 3.57, v_land = 0.329, E_out = 3.881, eta = 39.6% | s, m/s, J, % | Peak efficiency across the tested resistor set |
| Ref 4 | 100 ohm load vs. open circuit | t = 2.91 vs. 2.31, E_out = 3.134 vs. 0.000, eta = 32.0% vs. 0.0% | s, J, % | Weak braking raises impact loss; open circuit delivers zero energy |
| Your Trial | Record station, m/r/h or blades/pitch/v, R | Record t, v_land, E_out (or P_out), eta, ledger losses | s, m/s, J, W, % | Plot eta vs. R_load and verify sum(ledger) = E_in |
Lab report outline (blank template)
- Title: State the energy-conversion relationship investigated (e.g., load-resistance optimization in a falling-mass generator and wind turbine).
- Purpose: Define how electrical output integration and energy-ledger accounting test electromechanical efficiency and back-torque braking.
- Hypothesis: Predict how load resistance affects fall speed and where peak efficiency occurs between short and open circuit.
- Variables: List load resistance, drum radius, mass, or blade count/pitch/fan distance (independent);
t_fall,v_land,V,I,E_out/P_out, andeta(dependent); mode (controlled). - Data Table: Include setup,
E_in (J)(orP_wind (W)),R_load (ohm),t_fall (s),v_land (m/s),E_out (J)(orP_out (W)),eta (%), and major loss terms. - Analysis & Calculation: Plot
etavs.R_load(andP_windvs.v^3), verifyeta = eta_1 * eta_2 * eta_3, and compare experimental optimum load withsqrt((R_a+R_s)(R_a+R_s+K^2/b)). - Conclusion & Sources of Error: Explain why intermediate load maximizes efficiency and analyze how Real-mode friction/EMF tolerances and sensor quantization affect measured
eta.
Related electromagnetism and energy labs
Explore the underlying magnetic flux law in Electromagnetic Induction, compare thermal cycle efficiency in Heat Engines & PV Cycles, review mechanical energy conservation in Energy on a Track, or browse all Physics Simulations.
Common questions
How does a generator work when connected to an electrical load versus an open circuit?
Spinning the rotor induces voltage emf = K omega. With an open circuit, zero current flows so there is no magnetic braking torque and the falling mass accelerates freely; closing a resistive load lets current flow, producing opposing torque tau_elec = K I that slows the fall and delivers electrical power P = I^2 R.
What is the efficiency formula used in this generator simulation?
Overall energy efficiency is eta = E_out / E_in (or P_out / P_in for steady wind). In the falling-mass rig, E_in = m g h and E_out = integral V I dt across the load resistor; overall efficiency also factors into shaft capture (eta_1), electromechanical conversion (eta_2), and load fraction (eta_3).
Why does efficiency drop at both very low resistance (short circuit) and very high resistance (open circuit)?
In a short circuit (R = 0), large current dissipates all electrical power inside the generator's 12 ohm armature coil so load output is zero; in an open circuit (R = infinity), voltage is high but current is zero, again giving zero load power. Maximum efficiency occurs at an intermediate matched load (around 22–47 ohm here).
How does wind speed affect available power in the wind turbine simulation?
Wind kinetic power scales with the cube of airspeed (P_wind = 1/2 rho A v^3), so doubling wind speed multiplies available airflow power by eight while blade count, pitch angle, and load resistance determine how closely the rotor approaches optimal tip-speed ratio.
What is the Betz limit in wind energy conversion?
Momentum conservation across an actuator disk proves no open wind turbine can extract more than 16/27 (59.3%) of the kinetic power in the swept airstream because air must keep moving behind the blades.
How does the Village Planner connect generator efficiency to real-world engineering tradeoffs?
Students balance hydro head and river-flow limits, ridge and valley wind turbines, geothermal availability, and diesel backup against daily village demand (400 kWh/day), evening peak firm power (40 kW), annual cost, and CO2e emissions.