Skip to main content
Biology

Virtual Heart Dissection: Chambers & Circulation

Dissect a heart layer by layer. Where does a drop of blood go after it leaves the right side?

In the double-loop mammalian circulatory system, blood enters the right heart to travel to the lungs (pulmonary circuit, RV peak 25 mmHg) and returns to the thicker-walled left heart to supply the body (systemic circuit, LV peak 123 mmHg; LV wall 20.4 mm vs. RV wall 8.5 mm). In this 3D virtual heart dissection and circulation lab, students probe great vessels, cut transverse and frontal planes with calipers, count valve cusps, and run an 8-compartment hemodynamic model (baseline 75 bpm: 122/80 mmHg, 72 mL stroke volume, 5.4 L/min cardiac output, 75% venous O2).

  • 11 languages
  • Laptop · tablet · phone
  • Members

Create a free account to get 2 lifetime Free Lab Passes for any labs in the library. The course guide on this page stays free.

Inside this lab

  1. 1

    Preview

    • Driving question
    • What you will predict
    • Equipment and safety
  2. 2

    Lab

    • Lock in prediction
    • Run the experiment, measure and replay
    • Your notebook fills in as you go
  3. 3

    Check

    • Did the lab agree with you?
    • Claim, evidence, reasoning
    • Check questions and a printable lab report

Blood flow through the heart steps and chamber pressures

Follow a single drop of blood through the double-loop pathway in this heart dissection lab and heart anatomy interactive model. Both loops run in series—every milliliter pumped by the right ventricle travels through the lungs to the left ventricle—yet their pressures and wall thicknesses differ dramatically:

  1. Venae cavae (superior & inferior) -> Right atrium (RA) -> Tricuspid valve (3 flaps) -> Right ventricle (RV) -> Pulmonary valve (3 flaps) -> Pulmonary trunk & arteries -> Lungs (O2 rises from 75% to 98%).
  2. Pulmonary veins -> Left atrium (LA) -> Mitral / bicuspid valve (2 flaps) -> Left ventricle (LV) -> Aortic valve (3 flaps) -> Aorta -> Systemic body (delivers 250 mL O2/min at rest) -> returns to Venae cavae.
Structure / SiteDissection Ideal Wall ThicknessValve Flaps / Connected VesselHemodynamic Role (Ideal 75 bpm)
Left ventricle (LV)20.4 mmProbe via AortaGenerates 123 mmHg peak systolic pressure to drive systemic loop
Right ventricle (RV)8.5 mmProbe via Pulmonary trunkGenerates 25 mmHg peak systolic pressure to perfuse low-resistance lungs
Interventricular septum (IVS)18.0 mmSeparates LV and RVPrevents oxygenated and deoxygenated blood from mixing
Left & Right atria (LA / RA)2.5 mm / 2.0 mmPulmonary vein (LA), Venae cavae (RA)Thin-walled low-pressure receiving chambers
Valves (AV & Semilunar)—Mitral (2); Tricuspid, Pulmonary, Aortic (3 each)One-way pressure gates; closure produces LUB (AV) and DUB (semilunar)

Key circulation equations: Cardiac Output (L/min) = Stroke Volume (mL) * Heart Rate (bpm) / 1000, Pulse Pressure = Top (Systolic) - Bottom (Diastolic), and Aortic Compliance C = Delta V / Delta P.

Apparatus, safety notes, and step-by-step procedure

  • Apparatus: Two 3D benches: (1) Dissection tray with mammalian heart specimens, blunt vessel probe (aorta, pulmonary trunk, pulmonary vein, superior/inferior venae cavae), transverse and frontal section scalpel cuts, digital vernier calipers (0.1 mm resolution), and valve-cusp counter; (2) Circulation hemodynamic simulator (8 beats/run, heart rate 50–150 bpm in 5 bpm steps, aorta Stretchy vs. Stiff, arterioles Relaxed/Normal/Tight), real-time aortic/LV/RV/PA pressure trace, LUB/DUB valve audio cue, and venous O2 readout; plus Inside view (Levels, Valves & pressure, Artery wall).
  • Safety note (for physical lab prep): In a wet heart dissection, wear goggles, gloves, and a lab apron, cut away from your body on a dissection tray with a sharp scalpel, use a blunt probe to trace vessels without puncturing walls, and sanitize instruments and surfaces thoroughly afterward.
  1. Watch the Opening beating heart (75 bpm, 72 mL/beat) as a dye drop enters the right atrium and right ventricle, lock your prediction for where the drop travels next, and press Continue to watch it pass through the lungs (~5.7 s transit, O2 75% -> 98%) and return to the left heart.
  2. Open Investigate -> Dissection in Ideal mode, place a fresh heart specimen, and Probe all five great vessels (Aorta -> LV, Pulmonary trunk -> RV, Pulmonary vein -> LA, Superior & Inferior vena cava -> RA).
  3. Lock your Left vs. right wall prediction, make the Transverse (cross-section) cut across both ventricles, and measure LV wall (20.4 mm), RV wall (8.5 mm), and Septum (18.0 mm) with the digital calipers.
  4. Make the Frontal (front-to-back) cut to open all four chambers, measure LA (2.5 mm) and RA (2.0 mm) walls, and count cusps on the Tricuspid (3), Mitral (2), Pulmonary (3), and Aortic (3) valves.
  5. Switch to Investigate -> Circulation in Ideal mode and run the baseline setting (HR 75 bpm, Aorta = Stretchy, Arterioles = Normal), recording 122/80 mmHg, pulse pressure 42 mmHg, SV = 72 mL, CO = 5.4 L/min, and returning O2 = 75%.
  6. Lock your Stiffer aorta prediction, switch Aorta = Stiff (keeping 75 bpm and Normal arterioles unchanged), run 8 beats, and compare 150/65 mmHg (pulse pressure 85 mmHg) against the stretchy baseline.
  7. Return to Stretchy aorta and test Arterioles = Tight (142/102 mmHg, mean 123 mmHg) vs. Relaxed + 120 bpm (112/80 mmHg, CO = 6.8 L/min, returning O2 = 80%) to separate vascular resistance from arterial compliance.
  8. Open Inside view (Valves & pressure and Artery wall) to see how pressure crossovers open and snap shut each valve (LUB/DUB) and how elastic recoil sustains diastolic flow in a stretchy aorta.

Recording table and model reference data

Model reference data — run your own trials in the 3D lab. Values below reflect Ideal dissection caliper means and Ideal 8-beat steady-state circulation (V_tot = 5,000 mL, resting VO2 = 250 mL/min, SaO2 = 98%).

TrialIndependent Variable (Specimen Site or Circulation Setting)Dependent Variable (Ideal Model Output)UnitsObservation
Ref 1Dissection calipers: LV / RV / IVS / LA / RA walls20.4 / 8.5 / 18.0 / 2.5 / 2.0 mmmmLV / RV thickness ratio = 2.4:1, matching higher systemic workload
Ref 2Circulation baseline (75 bpm, Stretchy aorta, Normal tone)122/80 mmHg (PP = 42, MAP = 101), SV = 72 mL, CO = 5.4 L/min, O2 = 75%mmHg, mL, L/min, %LV peak = 123 mmHg vs. RV peak = 25 mmHg (~5x pressure ratio)
Ref 3Stiff aorta (75 bpm, Normal tone) vs. Tight arterioles (75 bpm, Stretchy)Stiff: 150/65 (PP = 85, MAP = 106); Tight: 142/102 (PP = 40, MAP = 123)mmHgStiffness widens pulse pressure (top up, bottom down); tight tone raises both
Ref 4Exercise-like (120 bpm, Stretchy aorta, Relaxed arterioles)112/80 mmHg, SV = 57 mL, CO = 6.8 L/min, returning O2 = 80%mmHg, mL, L/min, %Vasodilation prevents excessive pressure while higher CO delivers more O2
Your TrialRecord specimen/site or HR, aorta, tone, and mode/seedRecord wall (mm), cusps, Top/Bottom, SV, CO, and O2 %mm, mmHg, L/min, %Change one circulation knob at a time from 75 bpm Stretchy Normal

Lab report outline (blank template)

  1. Title: State the anatomical dissection measurement or hemodynamic relationship tested (wall thickness vs. pressure, aortic stiffness, or arteriole resistance).
  2. Purpose: Define how vessel probing, wall calipers, valve counts, and 8-beat circulation traces link heart structure to double-loop fluid mechanics.
  3. Hypothesis: Predict the LV-to-RV thickness ratio and how a stiff aorta vs. tight arterioles alters systolic, diastolic, and pulse pressure.
  4. Variables: Identify anatomical site/vessel, heart rate (50–150 bpm), aortic elasticity, and arteriole tone (independent); wall thickness (mm), valve flaps, Top/Bottom/MAP (mmHg), SV, CO, and venous O2 % (dependent); 5,000 mL blood volume and 250 mL/min resting O2 use (controlled).
  5. Data Table: Log vessel-to-chamber probe results, caliper readings (LV, RV, IVS, LA, RA), valve flap counts, and all circulation runs with PP and CO.
  6. Analysis & Calculation: Compute LV / RV wall ratio, verify CO = SV * HR / 1000, calculate Pulse Pressure = Top - Bottom, and estimate compliance C = Delta V / Delta P.
  7. Conclusion & Sources of Error: Explain why pulmonary and systemic circuits must move equal CO despite a 5x pressure difference, contrast stiffness vs. resistance effects on blood pressure, and discuss Real-mode specimen thickness spread (LV SD 2.1 mm), caliper error (0.3 mm), and beat-to-beat readout noise.

Connect heart-rate recovery to regulatory loops in Homeostasis & Feedback, trace fetal umbilical and maternal circulatory adaptations in Human Reproduction & Development, explore why cells consume O2 in Cellular Respiration, or browse Biology Simulations.

Common questions

What are the blood flow through the heart steps in exact order?

Deoxygenated blood flows from the superior and inferior venae cavae -> right atrium -> tricuspid valve -> right ventricle -> pulmonary valve -> pulmonary trunk/arteries -> lungs (oxygenated to 98% SaO2) -> pulmonary veins -> left atrium -> mitral (bicuspid) valve -> left ventricle -> aortic valve -> aorta -> systemic body -> back to venae cavae.

Why is the left ventricular wall more than twice as thick as the right ventricular wall?

In the dissection model, the left ventricle wall averages 20.4 mm compared with 8.5 mm on the right ventricle (ratio ~2.4:1). Although both ventricles pump the exact same stroke volume (~72 mL/beat), the left ventricle must generate roughly five times the peak systolic pressure (123 vs. 25 mmHg) to overcome high systemic arterial resistance.

What causes the LUB and DUB heart sounds in the circulation station?

LUB (S1) is produced when the atrioventricular valves (tricuspid and mitral) snap shut as ventricular contraction begins, preventing backflow into the atria. DUB (S2) occurs when the semilunar valves (aortic and pulmonary) snap shut as ventricular relaxation begins.

How many flaps (cusps) does each of the four heart valves have?

When you open the frontal cut and count valve cusps, the mitral (left AV) valve has 2 flaps, while the tricuspid (right AV), pulmonary semilunar, and aortic semilunar valves each have 3 flaps.

What happens to systolic and diastolic blood pressure when the aorta becomes stiff?

Reducing aortic compliance by half at 75 bpm with normal arterioles raises systolic (top) pressure from 122 to 150 mmHg while lowering diastolic (bottom) pressure from 80 to 65 mmHg. Pulse pressure more than doubles from 42 to 85 mmHg because a stiff aorta cannot stretch to buffer ejection or recoil smoothly during diastole.

How do cardiac output and venous oxygen saturation respond to arteriole tightening or higher heart rate?

Cardiac output equals stroke volume times heart rate (CO = SV * HR). At 75 bpm, tightening arterioles (1.3x resistance) raises mean pressure from 101 to 123 mmHg and slightly lowers SV (72 to 68 mL), whereas relaxing arterioles and raising HR to 120 bpm raises CO from 5.4 to 6.8 L/min.