Skip to main content
Chemistry

Buffer Solution Lab: pH, Capacity & Equilibria

Two liquids read the same pH. Add the same acid to both and predict what happens. Then design your own buffer.

A 0.10 M acetate buffer and unbuffered 1.75e-5 M HCl both start at pH 4.76, yet adding 5.00 mL of 0.200 M HCl drops unbuffered acid to pH 1.74 while the buffer holds steady at pH 4.58 and absorbs 20.52 mL before falling 1 pH unit. In this interactive 3D buffer solution lab, students test buffer capacity against dilution and acid-to-base ratio, prepare target-pH buffers from 1.00 M stocks, and compare Henderson-Hasselbalch estimates with equilibrium and meter readings.

  • 11 languages
  • Laptop · tablet · phone
  • Members

Create a free account to get 2 lifetime Free Lab Passes for any labs in the library. The course guide on this page stays free.

Inside this lab

  1. 1

    Preview

    • Driving question
    • What you will predict
    • Equipment and safety
  2. 2

    Lab

    • Lock in prediction
    • Run the experiment, measure and replay
    • Your notebook fills in as you go
  3. 3

    Check

    • Did the lab agree with you?
    • Claim, evidence, reasoning
    • Check questions and a printable lab report

Henderson–Hasselbalch equation, buffer capacity, and equilibrium solving

A buffer solution contains substantial amounts of both members of a weak conjugate acid–base pair (HA and A-): the conjugate base neutralizes added strong acid (A- + H3O+ -> HA + H2O), while the weak acid neutralizes added strong base (HA + OH- -> A- + H2O). For designing a buffer recipe, chemists estimate starting pH with the Henderson–Hasselbalch equation:

pH = pKa + log([A-]/[HA])

In this lab's Build a buffer station, all six reagent stocks (CH3COOH / NaCH3COO, pKa = 4.76; NaH2PO4 / Na2HPO4, second pKa2 = 7.20; and NH4Cl / NH3, pKa = 9.24) have identical 1.00 M stock concentrations and are diluted to a 100.0 mL batch. Because both stock molarities match (1.00 M) and share the same final volume, the mole ratio [A-]/[HA] simplifies to the stock volume ratio V_base / V_acid (pH ≈ pKa + log(V_base / V_acid)).

Worked numeric example (Phosphate buffer near pH 7.40): To prepare a 100.0 mL phosphate buffer using phosphoric acid's second dissociation (H2PO4- / HPO4^2-, Ka2 = 6.34 × 10^-8, pKa2 = 7.198), combine 5.0 mL of 1.00 M NaH2PO4 (5.0 mmol acid form) with 8.0 mL of 1.00 M Na2HPO4 (8.0 mmol base form) and dilute to 100.0 mL.

  • Ratio of conjugate base to acid: [HPO4^2-] / [H2PO4-] = 8.0 mL / 5.0 mL = 1.60.
  • Henderson–Hasselbalch preparation estimate: pH = pKa + log([A-]/[HA]) = 7.198 + log(1.60) = 7.198 + 0.204 = 7.402 (pH ≈ 7.40).

Keep three quantities distinct when interpreting your lab data: (1) the Henderson–Hasselbalch preparation estimate (plannedPH), which assumes ideal behavior and ignores water autoionization; (2) the true equilibrium pH (pHTrue), which the simulation solves iteratively from full charge balance, polyprotic equilibria, and (in Real mode) Davies ionic-strength activity coefficients plus dissolved CO2; and (3) the pH probe/meter reading, quantized to 0.01 pH and subject to calibration offset (±0.05 pH calibrated, ±0.20 pH uncalibrated) in Real mode. Buffer capacity is measured operationally here as the volume (mL) and amount (mmol) of 0.200 M HCl or 0.200 M NaOH absorbed before the solution leaves its ±1.00 pH band.

Apparatus, safety notes, and step-by-step procedure

  • Apparatus: 100 mL beaker on magnetic stir plate (50.0 mL sample portions), dual 50.0 mL Class A burettes (0.200 M HCl and 0.200 M NaOH, dispensing 1 drop, 0.1, 0.5, 1, 2, or 5 mL), calibrated digital pH meter and probe (0.01 pH resolution), 100.0 mL volumetric flask, 25 mL graduated pipet, six 1.00 M conjugate stock bottles (CH3COOH, NaCH3COO, NaH2PO4, Na2HPO4, NH4Cl, NH3), universal indicator, wash bottle, sample rack (distilled water, unbuffered HCl pH 4.76, 0.10 M acetate buffer, 10× diluted acetate buffer, 4:1 acetate buffer, 1:10 vinegar, sodium acetate, 0.9% saline, baking soda), and schematic particle lens.
  • Safety note (for physical lab prep): Wear splash goggles and gloves when dispensing 0.200 M HCl and NaOH, open concentrated ammonia (NH3) stocks only inside a fume hood, and use a pipet bulb—never pipet by mouth.
  1. Watch the Opening comparison of Solution A (unbuffered 1.75 × 10^-5 M HCl, pH 4.76) and Solution B (0.10 M acetate buffer, pH 4.76), lock your prediction, and dispense 5.00 mL of 0.200 M HCl into both beakers.
  2. Open Set up to calibrate the pH meter (pH 4.00 and 7.00 standards), review burette rinsing with titrant, verify the 50.0 mL sample volume, and put on safety goggles.
  3. In Investigate → Test a solution (Ideal mode), select Acetate buffer 0.10 M (50.0 mL) and add 0.200 M HCl in 5 mL steps, switching to 1 mL and 0.5 mL near the -1.00 pH band edge to bracket its acid capacity (20.52 mL).
  4. Switch to Acetate buffer, diluted 10× (0.010 M each), lock the dilution prediction, and add 0.200 M HCl in 0.5 mL and 0.1 mL increments to verify that starting pH stays near 4.76 while capacity drops nearly 10× (2.09 mL).
  5. Select Acetate buffer 4 : 1 (0.160 M CH3COOH, 0.040 M NaCH3COO), lock the ratio prediction, and run two separate trials—one with 0.200 M HCl (8.98 mL capacity) and one with 0.200 M NaOH (25.73 mL capacity).
  6. Open Inside view during a test run to inspect the Before–Change–After (BCA) mole bars and verify that added H3O+ converts acetate (A-) into acetic acid (HA) until the base reserve approaches exhaustion.
  7. Test a single-component sample (Vinegar, diluted 1:10 or Sodium acetate solution) to confirm that lacking one conjugate partner removes buffering in the unprotected direction.
  8. Open Build a buffer, choose the Phosphate pair (H2PO4- / HPO4^2-, pKa2 = 7.20), and set 5.0 mL acid stock and 8.0 mL base stock (1.00 M each, diluted to 100.0 mL) to target pH 7.40.
  9. Click Mix and measure to compare the Henderson–Hasselbalch planned pH (7.40) with the full equilibrium and meter readings, then test a 50.0 mL portion of your batch with 0.200 M HCl.
  10. Switch to Real mode, prepare the same phosphate batch with a calibrated probe, and compare the Ideal vs. Real meter reading to quantify ionic-strength activity and calibration uncertainty.

Recording table and model reference data

Model reference data — run your own trials in the 3D lab. Values below reflect Ideal mode (50.0 mL sample portions dosed with 0.200 M HCl or 0.200 M NaOH), showing exact equilibrium pH (pHTrue), rounded meter display (0.01 pH), and continuous ±1.00 pH buffer capacity.

TrialIndependent Variable (Sample & Composition)Dependent Variable (Equilibrium pH, Meter pH after +5.00 mL HCl, ±1 pH Capacity)UnitsObservation
Ref 1Unbuffered acid (1.75 × 10^-5 M HCl, 50.0 mL)Start 4.757 (meter 4.76); +5 mL HCl: 1.740 (meter 1.74); acid cap 0.04 mLM, mL, pHNo conjugate base reservoir; a single drop exits the ±1 band
Ref 20.10 M Acetate buffer (0.100 M HA + 0.100 M A-)Start 4.757 (meter 4.76); +5 mL HCl: 4.581 (meter 4.58); acid cap 20.52 mL / base cap 20.46 mLM, mL, pHSymmetric acid/base capacity (~4.10 mmol each)
Ref 310× Diluted acetate (0.010 M HA + 0.010 M A-)Start 4.759 (meter 4.76); +5 mL HCl: 2.040 (meter 2.04); acid cap 2.09 mL / base cap 2.05 mLM, mL, pHSame ratio holds starting pH, but 10× dilution cuts capacity ~10×
Ref 44:1 Acetate buffer (0.160 M HA + 0.040 M A-)Start 4.156 (meter 4.16); +5 mL HCl: 3.807 (meter 3.81); acid cap 8.98 mL / base cap 25.73 mLM, mL, pHLarger HA reservoir resists much more added NaOH than HCl
Your TrialRecord sample or batch (pair, V_acid, V_base), mode, calibrationRecord planned H–H pH, meter pH, ΔpH, and capacity (mL, mmol)mL, mmol, pHCompare Ideal vs. Real meter readings and check pH - pH0

Lab report outline (blank template)

  1. Title: Name the buffer system, comparison (concentration vs. ratio), or target-pH preparation objective.
  2. Purpose: State how burette dosing and batch preparation test the Henderson–Hasselbalch relation and buffer capacity.
  3. Hypothesis: Predict how dilution, conjugate ratio, and conjugate-pair pKa will change starting pH and ±1 pH capacity.
  4. Variables: Identify sample identity/concentration/ratio and added titrant volume (independent), meter pH and ΔpH (dependent), and fixed 50.0 mL portion volume, 0.200 M titrant molarity, stirring, and 25 °C temperature (controlled).
  5. Data Table: Log sample/batch composition, burette readings (mL), delivered titrant (mL and mmol), meter pH, ΔpH, and the ±1 pH capacity bracket.
  6. Analysis & Calculation: Compute plannedPH = pKa + log(V_base / V_acid), track reacted moles in a BCA table (mmol), convert held titrant volume to mmol = M × V, and compare Henderson–Hasselbalch estimates against equilibrium and meter pH.
  7. Conclusion & Sources of Error: Connect conjugate reserves to observed capacity, and analyze how ionic-strength activity (Davies deviation in Real mode), uncalibrated probe offset (±0.20 pH), wet burette dilution, or dissolved CO2 shift measured pH and apparent capacity.

Compare buffer regions directly on full titration curves in Acid–Base Titration, explore weak vs. strong acid dissociation in Acids, Bases & pH, examine carbonate buffering in seawater in Ocean Acidification, or explore all Chemistry Simulations.

Common questions

Why can two solutions start at the exact same pH yet respond completely differently to added acid?

Starting pH reflects only the current hydronium concentration, not the chemical reservoir available to neutralize incoming H3O+. A buffer contains substantial amounts of both a weak acid and its conjugate base, whereas dilute strong acid has no conjugate base reservoir to consume added acid.

What does the Henderson-Hasselbalch equation calculate, and when does it deviate from measured pH?

The Henderson-Hasselbalch equation pH = pKa + log([A-]/[HA]) gives a fast recipe estimate of buffer pH from the conjugate base-to-acid ratio. Actual pH diverges from that estimate when solutions are very dilute, when one component is nearly exhausted, or in Real mode where ionic-strength activity effects lower ion effectiveness.

Which pKa is used for the phosphate buffer system in this lab?

The phosphate buffer uses sodium dihydrogen phosphate (H2PO4-) as the weak acid and disodium hydrogen phosphate (HPO4^2-) as its conjugate base, so the relevant dissociation constant is phosphoric acid's second pKa2 = 7.20 (Ka2 = 6.34e-8).

How does diluting a buffer 10-fold affect its starting pH and buffer capacity?

Diluting both conjugate species equally preserves the [A-]/[HA] ratio, keeping Ideal starting pH virtually unchanged near 4.76. However, total moles of acid and base drop by a factor of 10, cutting the ±1 pH buffer capacity from about 20.5 mL down to 2.09 mL of 0.200 M HCl.

When a buffer has a 4:1 ratio of weak acid to conjugate base, does it resist acid or base better?

It resists added strong base better because it holds four times as much weak acid (HA) to neutralize incoming OH- as it holds conjugate base (A-) to neutralize incoming H3O+. In the 4:1 acetate sample, base capacity is 25.73 mL compared with 8.98 mL for acid.

How does the pH meter reading differ from the true equilibrium pH in Real mode?

In Ideal mode, the meter displays the exact equilibrium pH rounded to 0.01 pH units. In Real mode, the equilibrium solver includes Davies ionic-strength activity and dissolved atmospheric CO2, and the probe adds realistic calibration offset (up to ±0.20 pH uncalibrated or ±0.05 pH calibrated) plus ±0.01 pH read noise.